Sign In | Join Free | My chinacomputerparts.com |
|
Brand Name : HAIRF
Model Number : HADR 0692
Certification : CE 3C ISO
Place of Origin : CN
MOQ : 1 set
Price : 4999~8000USD
Payment Terms : T/T
Supply Ability : 800 unit/month
Delivery Time : 26~30 working days
Packaging Details : Wooden case for exporting shipping
cooling capacity : 5.9~102kw
voltage : 380v/3p/50hz
air supply : with air hood
warranty : 1 year free warranty
application : server room
HAIRF Environmental Control Systems High Precision Air Conditioning Unit
With the improvement of electricall equipment integration degree, equipment unit volurme power densityincrease, also more and more strict control of the indoor temperature, room temperature control equipment to ensure good indoor ernvironment is becoming more and more important to the equipment roomdedlicated HAIRF brand cooling air conditioning units,24"365 full-year refrigeration,effectivelyreduce the indoor termperature, and can consider introducing outdoor air to replace the wind, reduce therefrigeration system on time, according to the setting of indoor temperature and outdioor natural tempera-ture difference between air section.
Model:HADC/HAUC | 0061 | 0081 | 0101 | 0111 | 0131 | 0161 | 0191 | 0201 | |
Cooling capacity(1) | kw | 5.9 | 7.7 | 9.3 | 10.6 | 12.6 | 15.6 | 18.2 | 20.5 |
Air flow | m³/h | 1720 | 2150 | 2850 | 3200 | 3530 | 4800 | 5200 | 5700 |
EER | 3.6 | 3.65 | 3.55 | 3.65 | 3.6 | 3.65. | 3.65 | 3.66 | |
SHR | 0.95 | 0.93 | 0.95 | 0. 95 | 0.93 | 0.96 | 0.93 | 0.93 | |
| Compressor | |||||||||
Type | |||||||||
Capacity | kw | 1.5 | 1.9 | 2.2 | 2.3 | 3 | 3.6 | 4.3 | 5.3 |
Quantity | nr | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
Finned coll evaporator | |||||||||
Frontal suface | M2 | 0.29 | 0.29 | 0.47 | 0.47 | 0.47 | 0.65 | 0.65 | 0.65 |
Geometry | mm | ||||||||
Type of fins | |||||||||
FIn pitch | mm | ||||||||
Fan section | |||||||||
Type | |||||||||
Quantity | nr | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 |
Absorbed current | A | 1.2 | 1.6 | 3.2 | 3.2 | 3.2 | 3.8 | 3.8 | 3.8 |
Absorbed power | W | 165 | 282 | 500 | 563 | 563 | 668 | 668 | 850 |
AESP Max Speed(2) | Pe | 180 | 180 | 180 | 250 | 250 | 250 | 250 | 250 |
Air flter | |||||||||
Eficiency | |||||||||
Overall surface | M2 | 2.2 | 2.2 | 3.6 | 3.6 | 3.6 | 5 | 5 | 5 |
Fire reslstance dlass | |||||||||
I Electrical heaters | |||||||||
Total heating capaclty | kw | 2 | 2 | 2.5 | 2.5 | 2.5 | 5 | 5 | 5 |
Quantity | nr | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
Material | |||||||||
Humidifier | |||||||||
Capacty | Kg/h | 5-8 | 5-8 | 5-8 | 5-8 | 5-8 | 5-8 | 5-8 | 5-8 |
Absorbed power | kw | 2.25 | 2.25 | 2.25 | 2.25 | 2.25 | 2.25 | 2.25 | 2.25 |
Dimension&Weight | |||||||||
Height | mm | 1875 | 1875 | 1875 | 1875 | 1875 | 1875 | 1875 | 1875 |
Length | mm | 600 | 600 | 900 | 900 | 900 | 1200 | 1200 | 1200 |
Depth | mm | 449 | 449 | 49 | 449 | 449 | 449 | 449 | 449 |
Welght | kg | 150 | 157 | 195 | 210 | 230 | 245 | 255 | 270 |
Sound level | |||||||||
Sound pressure lel(3) | db(A) | 46 | 48 | 48 | 49 | 51 | 52 | 53 | 52 |
50kw precision air heating and cooling unit 380v/3phase/50hz PAC used in server room
Model : HADR/HAUR | 0201 | 0251 | 0261 | 0271 | 0301 | 0351 | 0401 | 1022 | |
Cooling capaciy(1) | kw | 21.2 | 23.2 | 26.8 | 27.3 | 31.5 | 35.6 | 41.2 | 102 |
Air flow | m³/h | 6530 | 7050 | 7280 | 8500 | 9000 | 10000 | 11000 | 24200 |
EER | 3.72 | 3.6 | 3.6 | 3.75 | 3.71 | 3.71 | 3.71 | 3.68 | |
SHR | 0.98 | 0.98 | 0.92 | 0.98 | 0.99 | 0.98 | 0.97 | 0.95 | |
Compressor | |||||||||
Type | Scroll | ||||||||
Capacily | kw | 5.2 | 5.5 | 5.9 | 6.2 | 7.4 | 8.3 | 9.3 | 22.4 |
Quantity | nr | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 2 |
I F hned coil evaporator | |||||||||
Frontal surface | m2 | 0.8 | 0.8 | 0.8 | 1.4 | 1.4 | 1.4 | 1.7 | 2.8 |
Geometry | mm | 25X21.65 | |||||||
Type of fins | Hydrophilic | ||||||||
Fin pich | mm | 1.8 | |||||||
Fan section | |||||||||
Type | Centrigugal fan | ||||||||
Quantity | nr | 1 | 1 | 1 | 1 | 1 | 1 | 2 | 3 |
Absorbed curent | A | 2.5 | 2.5 | 2.8 | 3.2 | 3.5 | 4.1 | 4.4 | 16.5 |
Absorbed power | W | 1050 | 1100 | 1200 | 1300 | 1320 | 2000 | 2150 | 6300 |
AESP Max Speed(2) | Pe | 360 | 360 | 360 | 380 | 380 | 355 | 355 | 400 |
Air flter | |||||||||
Eficiency | EU4 | ||||||||
Overall surface | m2 | 5.8 | 5.8 | 5.8 | 6.5 | 6.5 | 6.5 | 7.8 | 13.5 |
Fire resistance dass | |||||||||
I Electrical heaters | |||||||||
Total heating capacity | kw | 5 | 5 | 5 | 5 | 5 | 8 | 8 | 24 |
Quanlily | nr | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 4 |
Material | PTC | ||||||||
Humidifier | |||||||||
Capacily | Kg/h | 8-13 | 8-13 | 8-13 | 8-13 | 8-13 | 8-13 | 8-13 | 8-13 |
Absorbed power | kw | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
Dimension&Weight | |||||||||
Height | mm | 1998 | 1998 | 1998 | 1998 | 1998 | 1998 | 1998 | 1998 |
Length | mm | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1750 | 2500 |
Depth | mm | 795 | 795 | 795 | 795 | 795 | 795 | 795 | 795 |
Weight | kg | 375 | 385 | 393 | 450 | 490 | 590 | 595 | 1015 |
Sound level | |||||||||
Sound pressure level(3) | db(A) | 52 | 53 | 53 | 55 | 56.5 | 58 | 60 | 66 |
![]() |